通風(fēng)管道設(shè)要注意哪些細(xì)節(jié)
發(fā)布人:http://rdhw.com.cn 發(fā)布時(shí)間:2020-05-14 15:10:07
1.下降通風(fēng)機(jī)聲源噪聲
1. Reduce the sound source noise of ventilator
(1)合理選擇通風(fēng)機(jī)的機(jī)型。在噪聲控制要求高的場(chǎng)合,應(yīng)選用低噪聲通風(fēng)機(jī)。不同類型的通風(fēng)機(jī),在同樣的風(fēng)量、風(fēng)壓下,機(jī)翼型葉片的離心通風(fēng)機(jī)噪聲小,前向板型葉片的離心通風(fēng)機(jī)噪聲大。
(1) Select the type of ventilator reasonably. Low noise fan should be used in the situation of high noise control requirements. For different types of fans, under the same air volume and wind pressure, the centrifugal fan with wing blade has less noise, and the centrifugal fan with forward plate blade has more noise.
(2)通風(fēng)機(jī)的作業(yè)點(diǎn)應(yīng)挨近更率點(diǎn)。同一類型的通風(fēng)機(jī)效北越高,噪聲越小。為使通風(fēng)機(jī)的運(yùn)行工況點(diǎn)保持在通風(fēng)機(jī)的率區(qū),應(yīng)盡量避免用閥門進(jìn)行工況調(diào)節(jié)。如必須在通風(fēng)機(jī)壓出端設(shè)閥門時(shí),其設(shè)置的位置是距通風(fēng)機(jī)出口1m處。它能使2000Hz以下的噪聲下降。在通風(fēng)機(jī)入口處氣流應(yīng)保持均勻。
(2) The operation point of ventilator shall be close to the highest efficiency point. The higher the fan efficiency is in the north, the lower the noise is. In order to keep the operating point of the fan in the high efficiency area of the fan, it is necessary to avoid using the valve to adjust the operating point as much as possible. If it is necessary to set a valve at the press out end of the ventilator, the best position is 1 m away from the outlet of the ventilator. It can reduce the noise below 2000 Hz. The air flow shall be uniform at the fan inlet.
(3)在或許條件下恰當(dāng)下降通風(fēng)機(jī)的轉(zhuǎn)速。通風(fēng)機(jī)的旋轉(zhuǎn)噪聲與葉輪圓周速度10次方成份額,渦流噪聲與葉輪圓周速度6次方(或5次方)成份額。故下降轉(zhuǎn)速可下降噪聲。
(3) Reduce the fan speed properly under possible conditions. The rotating noise of the fan and the peripheral speed of the impeller are 10 times of the component amount, and the eddy noise and the peripheral speed of the impeller are 6 times (or 5 times) of the component amount. Therefore, reducing the speed can reduce the noise.
(4)通風(fēng)機(jī)進(jìn)、出口的噪聲級(jí)是通風(fēng)理、風(fēng)壓添加而增大的。因此,設(shè)計(jì)通風(fēng)體系時(shí),應(yīng)盡量削減體系的壓力丟失。當(dāng)通風(fēng)體系的總風(fēng)量和壓力丟失較大時(shí),可將其分為小體系。
(4) The noise level of fan inlet and outlet is increased by the addition of ventilation principle and air pressure. Therefore, when designing the ventilation system, the pressure loss of the system should be reduced as much as possible. When the total air volume and pressure loss of ventilation system is large, it can be divided into small systems.
(5)氣流在管道內(nèi)的流速不宜過(guò)高,避免引起再生噪聲。確定管道內(nèi)氣流流速應(yīng)根據(jù)不同要求按有關(guān)規(guī)定選取。
(5) The velocity of air flow in the pipeline should not be too high to avoid regeneration noise. The flow velocity in the pipeline shall be determined according to different requirements and relevant regulations.
(6)留意通風(fēng)機(jī)與電動(dòng)機(jī)的傳動(dòng)方法。選用直聯(lián)傳動(dòng)的通風(fēng)機(jī)噪聲更小,用聯(lián)軸器的次之,用沒(méi)有接縫的三角皮帶傳動(dòng)的稍差。通風(fēng)機(jī)應(yīng)配用低噪聲的電動(dòng)機(jī)。
(6) Pay attention to the driving method of fan and motor. The fan with direct drive has the least noise, the second with coupling, and the second with triangle belt without joint. Fans shall be equipped with low-noise motors.
2.傳遞途徑上對(duì)通風(fēng)機(jī)噪聲抑制
2. Noise suppression of ventilator in the transmission way
(1)在通風(fēng)機(jī)的進(jìn)、出風(fēng)口上裝配恰當(dāng)?shù)南暺鳌?br/>
(1) Install appropriate muffler on the air inlet and outlet of the ventilator.
(2)通風(fēng)機(jī)設(shè)減振基座,進(jìn)、出風(fēng)口用軟管聯(lián)接。
(2) The fan is equipped with a damping base, and the air inlet and outlet are connected with hoses.
(3)對(duì)通風(fēng)機(jī)做隔聲處理。如設(shè)置通風(fēng)機(jī)隔聲罩;在通風(fēng)機(jī)機(jī)殼內(nèi)襯只聲資料;將通風(fēng)機(jī)設(shè)置在專門的通風(fēng)機(jī)室內(nèi),并設(shè)置隔聲門、 隔聲窗或設(shè)置其他吸聲設(shè)施,或在通風(fēng)機(jī)室內(nèi)另設(shè)值班室等。
(3) Conduct sound insulation treatment for the fan. For example, the fan sound insulation cover shall be set up; the fan shell shall be lined with sound only data; the fan shall be set up in a special fan room, and sound insulation doors, sound insulation windows or other sound absorption facilities shall be set up, or another duty room shall be set up in the fan room.
(4)通風(fēng)機(jī)室的進(jìn)、排氣通道采納消聲辦法。
(4) Silencing method shall be adopted for the air inlet and exhaust channels of the fan room.
(5)將通風(fēng)機(jī)室布置在遠(yuǎn)離要求安靜的房間。
(5) Arrange the fan room away from the room requiring quiet.
3.及時(shí)保護(hù)保養(yǎng),定期檢保護(hù),及時(shí)更換破損零部件,排除反常,以發(fā)明低噪聲運(yùn)行條件。
3. Timely protection and maintenance, regular inspection and protection, timely replacement of damaged parts and components, elimination of abnormalities, in order to create low-noise operation conditions.
以上就是對(duì)濟(jì)南通風(fēng)管道的的詳細(xì)介紹,想要了解更多請(qǐng)點(diǎn)擊官網(wǎng)http://rdhw.com.cn
The above is a detailed introduction of Jinan ventilation pipeline. For more information, please click http://rdhw.com.cn
上一篇:玻璃鋼管道選購(gòu)時(shí)有哪些標(biāo)準(zhǔn)?